首页  |  期刊简介  |  编委会  |  稿件评审流程  |  学术道德规范  |  论文检索  |  期刊订阅  |  English
中文核心期刊
中国科技论文统计源期刊
国际刊号:1005-2615
国内刊号:32-1429/V
用户登录
  E-mail:  
  密  码:  
  作者 审稿  
  编辑 读者  
期刊向导
联系方式ʽ
  • 主管:工业和信息化部
  • 主办:南京航空航天大学
  • 国际刊号:1005-2615
  • 国内刊号:32-1429/V
  • 地址:南京市御道街29号
  • 电话:025-84892726
  • 传真:025-84892726
  • E-mail:tnc01@nuaa.edu.cn
  • 邮编:210016
刘宇芳 姜斌 易辉.基于数据预测的静电除尘器闪络故障恢复策略[J].南京航空航天大学学报,2017,49(4):496-503
基于数据预测的静电除尘器闪络故障恢复策略
Recovery Strategy for Flashover Fault of Electrostatic Precipitators Using Data Prediction
  
DOI:
中文关键词:  数据预测;故障恢复;智能控制;静电除尘器
英文关键词:data prediction; fault recovery; intelligent control; electrostatic precipitators (ESPs)
基金项目:
作者单位
刘宇芳 姜斌 易辉 1.南京航空航天大学自动化学院,南京,210016; 2.南京工业大学电气工程与控制科学学院,南京,211816 
摘要点击次数: 17
全文下载次数: 19
中文摘要:
      静电除尘器除尘效率极大地取决于电场电压输出,其控制关键在于电场发生闪络故障后的电压恢复策略。经典闪络故障恢复方法,如三线法、二线法,大多通过设定较长的低电压运行区间或设定输出电压上限实现电压输出控制,前者平均电压输出过低,而后者对电场特性的变换适应能力不足。为克服上述方法的不足,本文提出一种基于支持向量回归数据预测的方法,通过对临近故障电压的分析,推测出当前电场可能的闪络故障电压,并以此为基础,对二线法进行改进。4组不同工况的对比实验结果证明,本文方法不仅保留了三线法的环境自动适应能力,而且提高了系统的平均电压输出,其优越性得到验证。
英文摘要:
      The dust removing efficiency of electrostatic precipitators (ESPs) greatly depends on the voltage output of power supplies, and the fault recovery strategy when flashover fault happens plays an important role to ensure the efficiency. In classical recovery methods, such as three-line method and the two-line method, the output voltage of ESP power supplies has to operate in low value areas for a long time or to be given a limited up bond. Thus, the average output voltage is low. Moreover, for approach such as the two-line method, the adaptive capacity to environment is also poor when the electric field changes. For overcoming above deficiencies, this paper presents a new fault recovery strategy based on support vector regression (SVR). The strategy firstly predicts the voltage at which the soon-coming spark is likely to occur by analyzing near fault voltages. And then on this basis, it optimizes the process and parameters of two-line method to strengthen its adaptive capacity to environmental change and increase the average output voltage. Four groups of comparative experiments are made in the paper. Among all the experiments, the proposed strategy not only has the adaptability of the three-line method to the environmental change, but also yields a higher average output voltage than the traditional methods. Thus, the superiority of the proposed method is validated.